TRI-reinforcement for lintels of the openings

Tri-reinforcement is used for reinforcement of various constructions, lintel openings, load-bearing beams etc.

Tri-reinforcement is used as a distancer between the meshes to fix a set distance between the reinforcement bars. It is especially suitable for increased load. Ensures sustainable, stable fixation of the reinforcement during the concrete insertion.

The product complies with European standard EN 10080:2006 “Steel for reinforcement of concrete. Weldable reinforcing steel. General.”

The product complies with European standard EN 10080:2006 “Steel for reinforcement of concrete. Weldable reinforcing steel. General.”

Possibility to order galvanized.

Load-bearing beams or ceiling panel reinforcement frame

Reinforcement frame of lintel openings

Tri reinforcements (reinforcement frame)

H2

Overall height

70-300 mm

H1

Designed height

H1+ 5 mm

B1

Designed width

70-90 mm

1

Upper rebar

5 -14 mm

2

Diagonal rebar

5 – 7 mm

3

Lower rebars

5 – 14 mm

Ps

Diagonal step

200 mm

L

Maximum length

1.000 mm

U1

Diagonal rebar projection

1-4 mm

U2

Diagonal rebar projection

1-4 mm

Load resilience at a steady placement of the Tri reinforcement

Distance between tri reinforcements

Load resilience

Consumption per 1m2

1 m

120 kg/m2

1.00 jm/m2

0.8 m

150 kg/m2

1.25 jm/m2

0.6 m

200 kg/m2

1.10 jm/m2

0.4 m

300 kg/m2

2.50 jm/m2

Tri reinforcement (distancer between the meshes)

Tri reinforcements (reinforcement frame)

A

Designed height

40-300 mm

B

Overall height

A + 7 mm max

C

Bearing width

70-100 mm

D1

Upper rebar

4-8 mm

D2

Diagonal rebar

4-8 mm

D3

Lower rebars

4-8 mm

 

Diagonal step

200 mm

L

Length

2000 mm

H=125mm, 8/5/8mm, L=3000mm

H=120mm, 12/6/12mm, L=3000mm

 

Contact form