Tests - Mounting Plates
Test report No. 2501-02 – SIA AJV Office
- Test object:
- Mounting plates with sizes 50 x 80 mm and 80 x 120 mm.
- Various thicknesses tested.
- Test methods:
- Compression test according to the client's methodology.
- Testing carried out at the LU MMI Materials Testing Laboratory from January 24 to 28, 2025.
- Testing equipment:
- Load and deformation were measured with the ZwickRoell Z100 TEW electromechanical material testing equipment.
- Temperature was controlled with the ZwickRoell BTE-TC 12.00 temperature chamber.
- Calibration took place on January 24, 2023.
- Testing conditions:
- Three temperature regimes: -20 °C, 20 °C, and 40 °C.
- Each sample was conditioned for 10 minutes before testing.
- Sample groups and sizes:
- 150 samples were tested, marked with different labels according to size and temperature (e.g., S-2-C, L-3-H, etc.).
- Results:
- Deformation was measured at 35 kN and 100 kN loads.
- The average deformation values in various sample groups ranged from 0.067 mm to 3.343 mm, depending on the load and temperature.
- Notes:
- Samples were carefully prepared to avoid erroneous deformation values by removing protrusions from the top plates.
- Conclusions:
- The test results are representative only for the tested materials.
- The reproduction of the report is prohibited without full permission.